Modeling skin effect in large magnetized iron detectors

Authors: Incurvati, M.; Terranova, F.
The experimental problem of the calibration of magnetic field in large iron detectors is discussed. Emphasis is laid on techniques based on ballistic measurements as the ones employed by MINOS or OPERA.In particular, we provide analytical formulas to model the behavior of the apparatus in the transient regime, keeping into account eddy current effects and the finite penetration velocity of the driving fields. These formulas ease substantially the design of the calibration apparatus.Results are compared with experimental data coming from a prototype of the OPERA spectrometer.
Comment: 8 pages, 2 figures
Full-text available from: Cached PDF
Linked PDF (experimental)
Nucl.Instrum.Meth. A500 (2003) 441-445
http://arxiv.org/abs/hep-ex/0301015
Export record as: BibTeX
Citebase is currently only an experimental demonstration. Users are cautioned not to use it for academic evaluation yet. Citation coverage and analysis is incomplete and hit coverage and analysis is both incomplete and noisy.
Citations Downloads
To this article 1 10
To authors (mean) 5.00 9.67
Citations and downloads history

About this Record

Based on record (harvested at): oai:arXiv.org:hep-ex/0301015 (2007-08-16)
date 2003-01-10
subject High Energy Physics - Experiment
type text